Detection of Long Head of the Biceps Tendon Tears in Routine 3-T MRI Reports: A Retrospective Comparison with Arthroscopy
JOURNAL OF CLINICAL MEDICINE, cilt.15, sa.8947, ss.1-16, 2026 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 15 Sayı: 8947
- Basım Tarihi: 2026
- Doi Numarası: 10.3390/jcm15228947
- Dergi Adı: JOURNAL OF CLINICAL MEDICINE
- Derginin Tarandığı İndeksler: Academic Search Ultimate (EBSCO), Health Research Premium Collection (ProQuest), Scopus, Science Citation Index Expanded (SCI-EXPANDED), Chemical Abstracts Core, EMBASE
- Sayfa Sayıları: ss.1-16
- Açık Arşiv Koleksiyonu: AVESİS Açık Erişim Koleksiyonu
- Eskişehir Osmangazi Üniversitesi Adresli: Evet
Özet
Background/Objectives: This study evaluated routine clinical MRI reporting performance
for long head of the biceps tendon (LHBT) pathology against arthroscopy and explored
associated clinical factors. Methods: This retrospective study included 232 operated shoulders
from 229 patients undergoing preoperative non-contrast 3-T MRI and arthroscopy.
Diagnostic accuracy was assessed using outcome-specific paired observations. Clinical
associations were examined using logistic regression, with patient-cluster bootstrap internal
validation. MRI–arthroscopy intervals were evaluated in exploratory analyses. Results:
Arthroscopy identified structural tears in 93/230 shoulders. Among 226 shoulders with
paired tear-status data, reports detected 7/91 tears: sensitivity was 7.7%, specificity 97.0%,
and negative likelihood ratio 0.95. Detection rates were 5/88 for partial tears and 2/3 for
complete tears; the latter estimate is descriptive. Overall, 59/163 arthroscopically confirmed
LHBT abnormalities were report-negative. Age, groove tenderness, Speed test, and Yergason
test showed adjusted associations with tearing. The clinical model had an apparent
AUC of 0.858 and an optimism-corrected AUC of 0.851. Concomitant supraspinatus and
subscapularis tears showed crude associations with LHBT tearing (ORs 12.04 and 12.67).
Exploratory interval analyses detected no statistically significant differences. Conclusions:
Routine MRI reports had low sensitivity for LHBT tears in this surgically selected cohort.
These findings describe clinical reporting performance, not intrinsic MRI image capability.
A negative report should not alone exclude tearing. Clinical associations and model utility
require external validation.