Effects of Topical Products Used on the Facial Region on Intraoral Radiographic Image Parameters: An Exploratory In Vitro PSP Study


Baydar O., Kiliç E.

DIAGNOSTICS, cilt.16, sa.22, ss.1-18, 2026 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 16 Sayı: 22
  • Basım Tarihi: 2026
  • Doi Numarası: 10.3390/diagnostics16223885
  • Dergi Adı: DIAGNOSTICS
  • Derginin Tarandığı İndeksler: Academic Search Ultimate (EBSCO), Biomedical Reference Collection: Corporate Edition (EBSCO), Scopus, Science Citation Index Expanded (SCI-EXPANDED), EMBASE, Directory of Open Access Journals
  • Sayfa Sayıları: ss.1-18
  • Eskişehir Osmangazi Üniversitesi Adresli: Evet

Özet

Background/Objectives: This exploratory in vitro study evaluated the effects of topical facial products on quantitative pixel-level parameters of intraoral radiographic images under different exposure conditions using a photostimulable phosphor (PSP) system. Methods: Six groups were tested: inorganic sunscreen, organic sunscreen, BB cream, CC cream, silver (Ag) sulfadiazine 1%, and an untreated control. To isolate the individual radiographic signature of each formulation from anatomical confounders, the products were applied at a dose of 2 mg/cm2 to a homogeneous silicone soft-tissue phantom and imaged under three protocols (60 kVp/7 mA/0.080 s, pediatric anterior; 60 kVp/7 mA/0.160 s, adult anterior; 63 kVp/6 mA/0.200 s, adult posterior) with three independent acquisitions per group and protocol (54 images). Six parameters were measured in ImageJ: brightness, uniformity, signal-to-noise ratio, histogram clipping, noise, and uniformity index. Data were analyzed by two-way ANOVA with Dunnett post hoc testing and Benjamini–Hochberg (BH) correction. Results: Compared to the control, the BB cream showed significant differences in uniformity (higher SD), noise (higher), and uniformity index (higher; i.e., greater uniformity among the ROI means); the CC cream showed significant differences in histogram clipping (higher), noise (higher), and uniformity index (higher) (all BH-adjusted p ≤ 0.011). Silver sulfadiazine increased histogram clipping (BH-adjusted p = 0.002), while the inorganic sunscreen altered the uniformity index (BH-adjusted p = 0.042). The organic sunscreen did not differ from the control in the primary analysis. Neither exposure protocol nor the group-by-protocol interaction reached significance, although the study was powered only for large effects and exposure dependence cannot be excluded. Conclusions: Products containing metal oxides or silver sulfadiazine produced formulation-specific changes in quantitative imaging parameters, whereas the organic sunscreen tested in this study showed no significant difference from the control. This study did not test whether the observed differences are clinically visible or whether software processing can render them visible. The findings serve as a reference for subsequent research involving anatomical phantoms and observer-based studies.