Energetic and exergetic performance evaluation of a combined heat and power system with the micro gas turbine (MGTCHP)


Balli O., ARAS H.

INTERNATIONAL JOURNAL OF ENERGY RESEARCH, cilt.31, sa.14, ss.1425-1440, 2007 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 31 Sayı: 14
  • Basım Tarihi: 2007
  • Doi Numarası: 10.1002/er.1308
  • Dergi Adı: INTERNATIONAL JOURNAL OF ENERGY RESEARCH
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.1425-1440
  • Anahtar Kelimeler: combined heat and power, cogeneration, micro gas turbine, energy, exergy, energy analysis, exergy analysis, energy efficiency, exergy efficiency, SUSTAINABILITY
  • Eskişehir Osmangazi Üniversitesi Adresli: Evet

Özet

This study deals with the energetic and exergetic performance assessment of a combined heat and power system with micro gas turbine (MGTCHP). Quantitative energy and exergy balance for each component and the whole MGTCHP system was considered, while energy and exergy consumption within the system were determined. The performance characteristics of this MGTCHP system were evaluated using energy and exergy analyses methods. The energetic and exergetic efficiencies of the MGTCHP system are calculated as 75.99% with 254.55kW (as 99.15kW-electrical and 155.40kW-hot water(@363.15K)) and 35.80% with 123.61 kW (as 99.15 kW-clectrical and 24.46 kW-hot water(@363.15K)), respectively. The maximum energy loss and exergy consumption occur at 44.03 kW in the stack gas and 129.61 kW in the combustion chamber, respectively. Copyright (c) 2007 John Wiley & Sons, Ltd.