Dosimetric characteristics of line 142Pr beta sources in a prostate phantom for potential use in brachytherapy using two different dosimetry techniques
NUCLEAR ENGINEERING AND TECHNOLOGY, vol.58, no.5, pp.1-11, 2026 (SCI-Expanded, Scopus)
- Publication Type: Article / Article
- Volume: 58 Issue: 5
- Publication Date: 2026
- Doi Number: 10.1016/j.net.2026.104155
- Journal Name: NUCLEAR ENGINEERING AND TECHNOLOGY
- Journal Indexes: Scopus, Science Citation Index Expanded (SCI-EXPANDED), INSPEC, Directory of Open Access Journals
- Page Numbers: pp.1-11
- Open Archive Collection: AVESIS Open Access Collection
- Eskisehir Osmangazi University Affiliated: Yes
Abstract
The study aims to present the dosimetric properties of a novel line 142Pr beta-emitting source in an organ-specific prostate phantom for its potential use in prostate brachytherapy. The line 142Pr sources containing in capillary glass tubes, were produced through 141Pr(n,γ)142Pr reaction at a thermal neutron flux of 2.5x1012 n·cm−2·s−1 in a 250 kW Triga Mark II research reactor. Each tube containing ∼100 mg 141Pr (100%), when irradiated for 25 min, resulted in a dose rate of ∼2 Gy/h suitable for brachytherapy, even after a decay time of 10–12 h. Dosimetric characterization of line 142Pr sources were performed in terms of source strength, non-uniformity and active source length according to NCS-14, ICRU-72, and AAPM TG-60/TG-149 protocols by using EBT3 radiochromic film and ExradinW1 plastic scintillator detector (PSD). Measurements were conducted both in free-air and in water-equivalent solid phantoms, followed by dose mapping in a patient-specific, 3D printed anthropomorphic pelvic phantom representing prostate (target), bladder, and rectum (organs-at-risk). Although it does not exactly represent a brachytherapy treatment case, the dosimetric results indicate that line 142Pr sources can be used in brachytherapy applications at least as a medium-dose-rate brachytherapy source.
The produced novel line 142Pr beta sources exhibited low dose non-uniformities (0.8–3.7%) and source strengths of approx. 2–3 Gy/h at 10 h post-production. Dose profiles obtained on the prostate phantom indicated a steep beta dose fall-off and favorable dose distributions at OARs. The overall results indicate that line 142Pr beta sources meet the essential dosimetric requirements for brachytherapy sources, and it may serve as a promising candidate for future interstitial prostate applications, pending further pre-clinical evaluation.