The role of biomarkers in the diagnosis and treatment follow-up of idiopathic pulmonary fibrosis


KAYIKÇI A., ALATAŞ F., ALATAŞ İ. Ö., YILDIRIM H., Ozen H.

Sarcoidosis Vasculitis and Diffuse Lung Diseases, cilt.41, sa.2, 2024 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 41 Sayı: 2
  • Basım Tarihi: 2024
  • Doi Numarası: 10.36141/svdld.v41i2.15454
  • Dergi Adı: Sarcoidosis Vasculitis and Diffuse Lung Diseases
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Anahtar Kelimeler: biomarkers, diagnosis, follow-up, idiopathic pulmonary fibrosis
  • Eskişehir Osmangazi Üniversitesi Adresli: Evet

Özet

Background and aim: Idiopathic pulmonary fibrosis (IPF) is a chronic and progressive lung disease of unknown cause with a poor prognosis. The aim of our study is to determine the role of Krebs von den Lungen-6 (KL-6), Matrix metalloproteinase (MMP)-7, Surfactant protein A (SP-A), Surfactant protein D (SP-D), vascular endothelial growth factor (VEGF) and periostin in the diagnosis of IPF and in the response monitoring of patients treated. Method: 47 IPF patients, 27 non-IPF interstitial lung disease (ILD) patients and 21 healthy individuals were included in the study. Demographic data, pulmonary function test- Diffusing capacity of the lung for carbon monoxide (PFT-DLCO) measurements, High-resolution computed tomography (HRCT) findings of the patients were recorded, and serum samples were taken. Results: While periostin and SP-A levels were not significantly different between IPF and non-IPF ILD, they were significantly higher in both IPF and non-IPF ILD compared to healthy control group (p=0.002, p=0.006 for periostin and p=0.002, p<0.001 for SP-A, respectively). By receiver operating characteristic (ROC) analysis, the cut-off point for periostin to distinguish IPF is >594.5 pg/ml (sensitivity 72%, specificity 76%), while the cut-off point for SP-A is found >6.62 ng/ml (sensitivity 87.2%, specificity 57.1%). In the combined ROC analysis based on SP-A=6.62 ng/ml and periostin >634.6 pg/ml values, sensitivity was found to be 85% and specificity was 57%.Considering the correlation of forced expiratory volume in the first second (FEV1)(%), forced vital capacity (FVC)(%), restriction and diffusion severities with biomarker levels in the 6th month of IPF patients treated, a correlation was detected between MMP-7 levels and restriction severities (p=0.020), between KL-6 levels and restriction and diffusion severities (p=0.002), and between SP-A levels and FVC(%)(p=0.006). Conclusion: It is thought that biomarkers SP-A and periostin may contribute significantly to the diagnosis of patients with IPF, and SP-A, MMP-7 and KL-6 levels may contribute significantly to treatment follow-up.